Analysis of Video Monitoring System Maintenance

Video surveillance system monitoring center equipment such as matrix, video server, video wall, etc., is installed in the monitoring center room, equipment is concentrated in a relatively good indoor environment operation, monitoring center equipment failure rate is relatively small; and front-end camera, fast The ball is installed outdoors, and the video optical transceiver is installed in the outdoor distribution box. The equipment is exposed to the harsh environment such as wind and rain, high summer temperature and low temperature in winter, so the probability of failure is high. For the maintenance of the front-end monitoring equipment, it must be able to test the camera image, the image of the fastball, the PTZ control, the optical power of the video optical transceiver, and use a multimeter to test the power supply system, etc., so as to comprehensively solve the problem that the front-end equipment may appear faulty.

Camera maintenance
When the monitoring center fails to receive the image, the engineer must first detect whether the camera ball or the dome camera is normal. When detecting camera equipment, engineers use video monitoring comprehensive test instruments to do three aspects of detection: First, use the meter to test whether the camera has an image, the instrument's 3.5-inch color display can clearly display the image captured by the camera, if the meter does not receive The image or the received image is abnormal, indicating that the camera is faulty. Second, the video signal attenuation measurement using the monitor integrated tester is used to measure the camera's video complex level. The normal range is 800-1000mV, and the level is too low will cause the image to change. Dark, the level is too high will cause a virtual shadow; Third, use the instrument's multimeter to measure whether the camera's transformer power supply is normal, the general transformer output is DC 12V, the dome's transformer output is AC 24V, the transformer is the monitoring system failure rate comparison High accessories.

PTZ control and maintenance

In the security monitoring system, the pan/tilt or dome camera is widely used. The monitoring center staff can adjust the camera angle flexibly. When the pan/tilt or dome is out of control, or cannot be turned in a certain position, the engineer needs to carry the multifunctionality. The keyboard tests whether the pan/tilt or dome camera is rotating normally. However, different manufacturers of PTZ or dome cameras have their own proprietary protocols. When an engineering firm maintains a dome camera, it must bring with it a corresponding multi-function keyboard test. It may be necessary to bring multiple keyboards to test the use of different dome cameras. The engineering staff uses the video monitoring comprehensive tester to solve this problem, because it has embedded more than 30 kinds of protocols such as Pelco-D/P and BOSCH, and it is dedicated to testing the pan/tilt rotation testing function of the pan/tilt rotation. The personnel can rotate the instrument through the instrument and operate the PTZ to observe whether there is a card bit when the PTZ rotates.

Video light end maintenance

The video optical transceiver is divided into a transmitting end device and a receiving end device. The transmitting end device is placed in the same place as the camera. The engineering personnel usually perform maintenance testing on the transmitting end device. For the repair work of the optical transceiver, it is tested in three steps. First, use a multimeter of the video monitoring comprehensive tester to measure whether the power supply of the optical transceiver is normal, and the general power input is DC 5V. Second, measure whether the optical output power of the optical transceiver is normal. The emission wavelength of the transmitter is 1310n and the received wavelength is 1510n. The optical transceiver of 20KM is used. The general transmission power is about -9dBm. Third, test whether the video port of the optical transceiver and the RS485/RS232 communication are normal. The monitoring and comprehensive tester sends the standard color image strip image signal to the video optical transceiver. The monitoring center receives the test color strip sent from the video optical transceiver to indicate that the video transmission is normal. The RS485/RS232 data capture function of the instrument is used to receive the control signal of the optical transceiver. If receiving the control code sent by the monitoring center, it indicates that the optical transceiver's RS485/RS232 communication is normal.

BNC coaxial cable transmission maintenance

In the current video surveillance system, traditional analog images dominate, and IP digital cameras have become popular in the future due to compatibility issues. In general, small-area monitoring systems such as factories and buildings directly use BNC coaxial cables to transmit images. BNC coaxial cables have weak anti-interference, and each BNC cable can only transmit one video, but due to the small monitoring area, the same Shaft cable transmission is relatively low cost, and BNC coaxial cable is widely used. BNC cables are degraded or even interrupted due to ageing, man-made damage, and other reasons. In the maintenance work, it is usually necessary to detect whether the BNC cable has a problem.

During the maintenance of the cable, engineers use the integrated tester to do three steps. First, at the camera end, the BNC cable is connected to the meter and the standard image color bar is sent using the image generator of the meter. Under normal circumstances, The monitor of the monitoring center should receive the same color pattern bar. This step judges whether the BNC line is disconnected, whether the monitoring center receives the image color is normal or not. Second, in the monitoring center, the instrument uses the video signal attenuation measurement function, The attenuation of the measured video complex level after transmission through the BNC cable is too large. Normally, it is 800-1000mV. The phenomenon of image jitter, image dimming, etc. is caused by the attenuation of the video. Thirdly, if the BNC cable is disconnected in the middle, because the BNC cable is buried in the slot, the engineer has no test tool to find the fault point. Using the test function of the integrated test meter, the meter emits a signal and measures the fault. Point location, for the engineering staff to immediately find the location of breakpoints, greatly improving work efficiency.

Optical fiber transmission maintenance

Optical fiber transmission has the characteristics of large capacity, high speed, and high stability. Video monitoring systems increasingly use optical fiber devices such as video optical transceivers and optical transceivers to transmit video images and control signals. Large-scale monitoring systems, such as highway monitoring and monitoring in safe cities, use optical fiber transmission to achieve highly stable video transmission. With the development of optical fiber communication technologies, the prices of video optical cables and optical fiber cables are getting lower and lower, and video monitoring systems use optical fibers. Transmission has become very popular. Optical fiber transmission is usually used for signal transmission between a few hundred meters to 100 kilometers, and detection of fiber optic cables is also an indispensable step. For fiber maintenance, engineers must use specialized fiber-optic test instruments such as light sources, optical power meters, and OTDRs. The stable light source is designed to emit laser light with a high stable power value. The laser light has a certain attenuation after being transmitted through the optical fiber. The power value after transmission through the optical fiber is measured by an optical power meter to calculate the loss value of the optical fiber. Measuring the time-consuming of the optical fiber must be matched with the light source and the optical power meter in order to prepare to calculate the optical fiber loss; and the OTDR is an instrument for measuring the position of the break point of the optical fiber. It detects how many kilometers the optical fiber is disconnected, but the cost of the OTDR is low. Too high, smaller contractors can use optical fiber barriers to measure breakpoints. For small-scale contractors, the most needed optical fiber measurement tool is the optical power meter. Because long-distance optical cables are usually maintained by telecommunication operators or broadcasting and television systems, small-scale engineers only need to measure the power and fiber loss of optical fiber equipment. Finding the problem is enough.

When maintaining optical fiber, engineers use the optical power measurement function of the monitoring integrated tester to switch to the corresponding wavelength to measure multi-mode and single-mode optical fibers. Optical-connected optical communication devices (such as video optical transceivers and optical transceivers) are normal. In this case, an optical signal will be emitted. If the meter does not receive an optical signal, -70dBm is displayed, indicating that the optical fiber is inaccessible. It is necessary to check whether the optical fiber jumper or the optical cable is disconnected or damaged.

PVC Ceiling Tiles(pvc 3d decoration ceiling)

As new materials for ceiling decoration. 

The 3D Ceiling Tiles offer various patterns for choosing,such as marbling,wooden,others design.

More nature,elegant looking.

Substitute the marble tiles,PVC tiles,Wood tiles,etc. Used widely in interior decoration.

Feature

1. Fireproof

PVC 3D Ceiling Tiles is non-flammable and conforms to the national grade B1 standard (GB8624-2012 Grade B1).

2. Water-proofing and moisture-proofing

The product is allowed to long-term expose to moist environment.

3. Easy to install

Pvc 3D Ceiling Tiles is easy to cut, saw nail, stick. it has a smooth finish one side that can be taped and jointed ready for decoration including wallpapering, painting, texture coat and veneer, and a rougher side for tiling.

5. Environment

PVC 3D Ceiling Tiles does not contain any organic solvents, formaldehyde, asbestos, oils or other toxic substances that can have a negative impact on the environment and waterways.


Specification size

1220mm*2440mm

Surface Finish

High UV coating

Thickness

1-9mm

Color

Customized colors

Hardness

3H-6H

Materials

PVC

Type

PVC 3D Ceiling Tiles

Installation

Easy installation

Life Span

15 years

Place of original

China


wood grain PVC ceiling

PVC 3D Ceiling Tiles

Shower Bath Pvc 3D Flooring Tiles,Pvc Bathroom Ceiling Tiles ,Waterproof Pvc 3D Ceiling,Acoustic Panel 3D Ceiling Tiles

Shandong Kingmarble Decoration Materials Co.,Ltd , http://www.pvcmarblepanel.com

This entry was posted in on